Bay Area

LOCATION
Bay Area

  • Platform
  • Services
  • Technical
  • About
Current
1.67 Gb/s
Peak
21.16 Gb/s

Interface & cabling specifications

    Interface & cabling specifications

    Interface typeCableConnector (*2)WavelengthMax. Distance (*1)Tx (dBm) (*3)Rx (dBm)
    10GEBase-LR
    SMLC/PC1310 nm10 km-8.0 ... 0.5-14.4 ... -0.5
    100GEBase-LR4
    SMLC/PC1310 nm10km-4.5 ... 4.5-8.6 ... 4.5
    100GEBase-LR1
    SMLC/PC1310nm10Km+2.5-2.4 … - 4.0
    400GEBase-LR4SMLC/PC1310nm10Km+2.00 … +3.3-10.0 … -13.0
    400GEBase-ZR+SMLC/PC1550nm40Km0.0-10.0 … -20.0

    Interface & cabling specifications

    Interface type
    CableConnector (2)WavelengthMax. Distance (1)Tx (dBm) (4)Rx (dBm)
    1000BaseSX
    MMSC/PC850 nm250 m-9.5-17
    1000BaseLX (3)
    SMSC/PC1310 nm5 km-9.5 ... -3.0-20.0 ... -3.0
    10GEBase-LR
    SMSC/PC1310 nm10 km-8.0 ... 0.5-14.4 ... -0.5
    100GBase-LR4
    SMSC/PC1310 nm10 km-4.5 ... 4.5-8.6 ... 4.5

    (1): This concerns 'customer cable', i.e. the maximum distance between customer equipment and the AMS-IX patch panel.

    (2): The type depends on the housing site; certain MMRs contain panels with LC/PC connectors.

    (3): Brocade/Foundry LX ≡ Cisco LH

    (4): as measured at the AMS-IX patch panel

    *(1): This concerns 'customer cable', i.e. the maximum distance between customer equipment and the AMS-IX patch panel. These numbers might be impacted due to connections or equipment capabilities.

    *(2): The connector type depends on the housing site and connector type used in the MMR's

    *(3): As measured at the AMS-IX patch panel

    Subscribe to our newsletter

    Got a question?